{"id":1973,"date":"2015-09-16T12:11:18","date_gmt":"2015-09-16T12:11:18","guid":{"rendered":"http:\/\/hydrogen.wsu.edu\/?page_id=1973"},"modified":"2016-10-13T18:46:31","modified_gmt":"2016-10-14T01:46:31","slug":"container","status":"publish","type":"page","link":"https:\/\/hub.wsu.edu\/ise\/design\/container\/","title":{"rendered":"Container"},"content":{"rendered":"<br \/>\n<section id=\"builder-section-1443112934731\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<p style=\"text-align: left\">Our method of using shipping containers to house our hydrogen fueling station lends a new level of modularity to the hydrogen fueling world that has never been seen before. This modularity will give us the unmatched ability to drag and drop our fueling stations to many location based on customer needs or desires. By evolving the concept of what a mobile hydrogen station can be, we have created a paradigm shift in the modularity and mobility of hydrogen fueling.<\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1442592696698\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<header>\n<h2>Background<\/h2>\n<\/header><\/div>\n<\/section>\n<section id=\"builder-section-1442592724659\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<header>\n<h2>Selected Design<\/h2>\n<\/header>\n<p><strong>\u00a0Needed Modifications:<br \/>\n<\/strong><\/p>\n<p>The following modification have been determined to be necessary to meet the requirements of the container.<\/p>\n<p><strong>Exterior Paint:<\/strong><\/p>\n<p>Flat white painted exterior to allow for the easy addition of logos and sponsorship. (Done By Dry Box)<\/p>\n<p><strong>Spark Proof Vents:<\/strong><\/p>\n<p>Two standard vent holes in the roof of the container to circulate air flow through the box. (Done By Dry Box)<\/p>\n<p><strong>Flat Steel Flooring:<\/strong><\/p>\n<p>Sheet of one eight inch steel covering the container floor installed on supports. (Done by us)<\/p>\n<p><strong>Insulation:<\/strong><\/p>\n<p>The insulation will consist of dry wall hung on the inside of the container over the courrigation with an insulating foam filling the gap between the two. (Done by us)<\/p>\n<p><strong>Roll Up Door:<\/strong><\/p>\n<p>A 4 foot roll up door will be placed on the end of the long side of the container and will house the user interface and pump (Done by Dry Box)<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1476402609163\" class=\"row single h1-header gutter pad-top\">\n<div style=\"\" class=\"column one expand\">\n<h2>&#8212; Expand \/ Collapse Technical Information &#8212;<\/h2>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1442592314291\" class=\"row single gutter pad-top expandable\">\n<div style=\"\" class=\"column one \">\n<header>\n<h2>Required Specifications<\/h2>\n<\/header>\n<p>The following are the necessary and wanted requirements the container will need to meet in order for our system to be successful.<\/p>\n<p>MUSTS:<\/p>\n<ul>\n<li>Fit all necessary components<\/li>\n<li>Securely mount all components in place for transport<\/li>\n<li>Meet necessary power components<\/li>\n<li>Be able to transport to competition location and any permanent location<\/li>\n<li>Meet all DOT regulations<\/li>\n<li>Meet all regulations for the shielding for a hydrogen liquefaction system<\/li>\n<li>protect the container from both weather and trespassers<\/li>\n<\/ul>\n<p>SHOULDS:<\/p>\n<ul>\n<li>Provide exterior lighting for the out side of the container<\/li>\n<li>Cosmetically look like a fueling station<\/li>\n<li>Be securely mounted in a permanent location<\/li>\n<li>Act as a training tool for first responders<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1442592710844\" class=\"row single gutter pad-top expandable\">\n<div style=\"\" class=\"column one \">\n<header>\n<h2>Concept Scoring<\/h2>\n<\/header>\n<p style=\"text-align: justify\"><strong>Container<strong>\u00a0Option Specifications<\/strong><\/strong><\/p>\n<p style=\"text-align: justify\">The chart below shows the comparison between the measurable qualities of the containers to find which aspects are important to the selection of the correct unit. The left hand horizontal column shows the requirements we need to meet as set by the competition and customer. The vertical column shows the measurable characteristics of containers that will help to meet these requirements. Then the primary use of this tool can be shown in the central area where the horizontal and vertical columns are combined to show the relationships between each of the different characteristics. Using this tool we were able to determine which characteristics of a container are best suited to meet the requirements of the task and will continually help us choose three different containers which will act as viable options, they are profiled below.<\/p>\n<p><a href=\"https:\/\/hydrogen.wsu.edu\/wp-content\/uploads\/sites\/44\/2015\/09\/Pasted-image-at-2015_12_09-01_51-PM.png\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3580\" src=\"https:\/\/hydrogen.wsu.edu\/wp-content\/uploads\/sites\/44\/2015\/09\/Pasted-image-at-2015_12_09-01_51-PM.png\" alt=\"Pasted image at 2015_12_09 01_51 PM\" width=\"890\" height=\"416\" \/><\/a><\/p>\n<p>The standard steel container and the insulated container rate the highest when all aspects are compared.<\/p>\n<p>These two options best meet our needs and were the two highest scoring options from our chart above so we compared them further.<\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1443197831918\" class=\"row halves gutter pad-top expandable\">\n<div style=\"\" class=\"column one \">\n<header>\n<h2>Advantages<\/h2>\n<\/header>\n<p><strong>Advantages:<\/strong><\/p>\n<p>Standard corrugated 20\u2019 Steel Shipping Container:<\/p>\n<p>\u2022 Voluminous (~2400 cubic feet)<br \/>\n\u2022 Low initial Investment<br \/>\n\u2022 High load capacity<br \/>\n\u2022 Portable using current transportation network<br \/>\n\u2022 Highly modifiable<\/p>\n<p>Insulated\/Refrigerated Shipping Container:<\/p>\n<p>\u2022 Voluminous (~2000 cubic feet)<br \/>\n\u2022 Interior Lighting\/Remote Monitoring<br \/>\n\u2022 High load capacity<br \/>\n\u2022 Insulated<br \/>\n\u2022 Temperature controlled<\/p>\n<p>&nbsp;<\/p>\n<\/p><\/div>\n<div style=\"\" class=\"column two \">\n<header>\n<h2>Disadvantages<\/h2>\n<\/header>\n<p>&nbsp;<\/p>\n<p><strong>Disadvantages:<\/strong><\/p>\n<p>Standard corrugated 20\u2019 Steel Shipping Container:<\/p>\n<p style=\"padding-left: 30px\">\u2022 \u201cBlank Slate\u201d<br \/>\n\u2022 Requires extensive retrofitting<br \/>\n\u2022 Lacks insulation or ventilation<\/p>\n<p>Insulated\/Refrigerated Shipping Container:<\/p>\n<p style=\"padding-left: 30px\">\u2022 Retrofitting may be necessary<br \/>\n\u2022 External Power Required<\/p>\n<p style=\"padding-left: 30px\"><\/div>\n<\/section>\n<section id=\"builder-section-1443209826984\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<header>\n<h2>Selected Design Rationale<\/h2>\n<\/header>\n<p><strong>Current Recommendation\u00a0<\/strong><\/p>\n<p>We are recommending the standard steel corrugated 20&#8242; shipping container. We believe that based on the analysis of the current options this particular configuration would best fit our needs for a container that will hold all of the individual subsystems. This container option will require all shielding and fire protection to be retrofitted but we believe that it currently represents the best option to begin the building of our H2 Refuel Station.<\/p>\n<p>We have chosen to order this container from Dry Box USA. This container will painted flat white and shall include the modifications of one roll up door on the side of the container to house the user interface, also two 3ftx3ft viewing windows will be installed for the purpose of educational demos of the inner workings of the system and lastly 2 spark proof vents will be installed into the roof of the container.<\/p>\n<p style=\"text-align: center\"><a href=\"https:\/\/hydrogen.wsu.edu\/wp-content\/uploads\/sites\/44\/2015\/09\/spill-2.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-full wp-image-3585\" src=\"https:\/\/hydrogen.wsu.edu\/wp-content\/uploads\/sites\/44\/2015\/09\/spill-2.jpg\" alt=\"spill 2\" width=\"922\" height=\"692\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<\/p><\/div>\n<\/section>\n<section id=\"builder-section-1449789745975\" class=\"row single gutter pad-top\">\n<div style=\"\" class=\"column one \">\n<header>\n<h2>Future<\/h2>\n<\/header><\/div>\n<\/section>\n<section id=\"builder-section-1476402812612\" class=\"row single gutter pad-top expandable\">\n<div style=\"\" class=\"column one \">\n<header>\n<h2>Paradigms<\/h2>\n<\/header>\n<p><strong>Types of Containers Available<\/strong><\/p>\n<p>Standard Steel Container<\/p>\n<ul>\n<li>Double doors on each end, or doors over the entire length of one side<\/li>\n<li>Very in sizes from 10ft to 53ft in length, standard sizes being 20ft and 40ft and heights of 8ft<\/li>\n<li>Easy to repair<\/li>\n<li>susceptible to corrosion<img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"http:\/\/www.tis-gdv.de\/tis_e\/containe\/arten\/standard\/10acont.jpg\" alt=\"\" width=\"412\" height=\"229\" \/><\/li>\n<\/ul>\n<p>Ventilated Containers<\/p>\n<ul>\n<li>Base of a Steel Container<\/li>\n<li>Ventilation slots in the top and bottom of the side rails<\/li>\n<li>Opening do not allow rain or spray to enter the container<br \/>\n<img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"http:\/\/www.tis-gdv.de\/tis_e\/containe\/arten\/ventil\/1001a.jpg\" alt=\"\" width=\"401\" height=\"258\" \/><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"http:\/\/www.tis-gdv.de\/tis_e\/containe\/arten\/ventil\/1000a.jpg\" alt=\"\" width=\"411\" height=\"243\" \/><\/li>\n<\/ul>\n<p>Insulated and Refrigerated Containers<\/p>\n<ul>\n<li>Mainly available in 20ft and 40ft length sizes<\/li>\n<li>Contains an integral refrigeration system<\/li>\n<li>Ensures circulation of cold air<\/li>\n<li>Insulated for maximum efficiency<\/li>\n<\/ul>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"http:\/\/www.tis-gdv.de\/tis_e\/containe\/arten\/kuehlcon\/foto01.jpg\" alt=\"\" width=\"379\" height=\"249\" \/><\/p>\n<p>Hard Top Container<\/p>\n<ul>\n<li>Made of corrugated steel and available at all standard sizes<\/li>\n<li>Roof and end of the container are removable<img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"http:\/\/www.tis-gdv.de\/tis_e\/containe\/arten\/hardtop\/1a.jpg\" alt=\"\" width=\"423\" height=\"270\" \/><\/li>\n<\/ul>\n<p>Bulk Containers<\/p>\n<ul>\n<li>Contains roof hatches for loading<\/li>\n<li>made for holding bulk cargo such as biomass\/food stuffs<\/li>\n<li>Equipped with forklift pockets for lifting<\/li>\n<\/ul>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"aligncenter\" src=\"http:\/\/www.tis-gdv.de\/tis_e\/containe\/arten\/bulk\/1000a.gif\" alt=\"\" width=\"351\" height=\"236\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<\/p><\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p style=\"text-align: left\">Our method of using shipping containers to house our hydrogen fueling station lends a new level of modularity to the hydrogen fueling world that has never been seen &#8230; <a href=\"https:\/\/hub.wsu.edu\/ise\/design\/container\/\" class=\"more-link\"><span class=\"more-default\">&raquo; More &#8230;<\/span><\/a><\/p>\n","protected":false},"author":323,"featured_media":4742,"parent":2908,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"template-builder.php","meta":[],"wsuwp_university_location":[],"wsuwp_university_org":[],"_links":{"self":[{"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/pages\/1973"}],"collection":[{"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/users\/323"}],"replies":[{"embeddable":true,"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/comments?post=1973"}],"version-history":[{"count":20,"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/pages\/1973\/revisions"}],"predecessor-version":[{"id":4876,"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/pages\/1973\/revisions\/4876"}],"up":[{"embeddable":true,"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/pages\/2908"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/media\/4742"}],"wp:attachment":[{"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/media?parent=1973"}],"wp:term":[{"taxonomy":"wsuwp_university_location","embeddable":true,"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/wsuwp_university_location?post=1973"},{"taxonomy":"wsuwp_university_org","embeddable":true,"href":"https:\/\/hub.wsu.edu\/ise\/wp-json\/wp\/v2\/wsuwp_university_org?post=1973"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}